On this page
dladm_vnic - Manage VNICs on Solaris/illumos systems.
New in version 2.2.
Synopsis
- Create or delete VNICs on Solaris/illumos systems.
 
Parameters
| Parameter | Choices/Defaults | Comments | 
|---|---|---|
| link  
        required
         | 
      
        
        VNIC underlying link name.
         | 
     |
| mac | Default: 
        "no"
         | 
      
        
        Sets the VNIC's MAC address. Must be valid unicast MAC address.
        
       aliases: macaddr  | 
     
| name  
        required
         | 
      
        
        VNIC name.
         | 
     |
| state | 
       
  | 
      
        
        Create or delete Solaris/illumos VNIC.
         | 
     
| temporary  
        bool
         | 
      
       
  | 
      
        
        Specifies that the VNIC is temporary. Temporary VNICs do not persist across reboots.
         | 
     
| vlan | Default: 
        "no"
         | 
      
        
        Enable VLAN tagging for this VNIC. The VLAN tag will have id vlan.
        
       aliases: vlan_id  | 
     
Examples
# Create 'vnic0' VNIC over 'bnx0' link
- dladm_vnic:
    name: vnic0
    link: bnx0
    state: present
# Create VNIC with specified MAC and VLAN tag over 'aggr0'
- dladm_vnic:
    name: vnic1
    link: aggr0
    mac: '00:00:5E:00:53:23'
    vlan: 4
# Remove 'vnic0' VNIC
- dladm_vnic:
    name: vnic0
    link: bnx0
    state: absent
  Return Values
Common return values are documented here, the following are the fields unique to this module:
| Key | Returned | Description | 
|---|---|---|
| link  
        string
         | 
      always | 
        
        VNIC underlying link name
         Sample:
        
       
        igb0
         | 
     
| mac  
        string
         | 
      if mac is specified | 
        
        MAC address to use for VNIC
         Sample:
        
       
        00:00:5E:00:53:42
         | 
     
| name  
        string
         | 
      always | 
        
        VNIC name
         Sample:
        
       
        vnic0
         | 
     
| state  
        string
         | 
      always | 
        
        state of the target
         Sample:
        
       
        present
         | 
     
| temporary  
        boolean
         | 
      always | 
        
        VNIC's persistence
         Sample:
        
       
        True
         | 
     
| vlan  
        int
         | 
      success | 
        
        VLAN to use for VNIC
         Sample:
        
       
        42
         | 
     
Status
This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.
Maintenance
This module is flagged as community which means that it is maintained by the Ansible Community. See Module Maintenance & Support for more info.
For a list of other modules that are also maintained by the Ansible Community, see here.
Author
- Adam Števko (@xen0l)
 
Hint
If you notice any issues in this documentation you can edit this document to improve it.
© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.